Combo Pack -TwinStim Plus +US 2000 Portable Ultrasound+5/pk2x2"Pads+3gel

  • Combo Pack -TwinStim Plus +US 2000 Portable Ultrasound+5/pk2x2"Pads+3gel
  • Product Code: TwinStim Plus +US 2000 Portable Ultrasound
  • Reward Points: 918
  • Availability: In Stock
  • $459.00


Free Shipping

Combo Pack -TwinStim Plus +US 2000 Portable Ultrasound+10/pk2x2"Pads

 

*NEW* Portable Ultrasound US Pro 2000 2nd Edition - Continuous Pulse + Heat

 

 

  • nscerebrally.
  • Stimulation should not be applied over swollen, infected, or inflamed areas or skin eruptions.
  • Stimulation should not be applied over, or in proximity to, cancerous lesions.

Roscoe Medical, Inc.
21973 Commerce Parkway
Strongsville, OH 44149
©Roscoe Medical, Inc. www.RoscoeMedical.com

*NEW* US Pro 2000 2nd Edition - Continuous Pulse + Heat

Description

Twin Stim Plus Digital TENS and EMS Unit -info below

below

Carrying Case Yes
Unit Size Medium
Output Power 0-80 mA
Tens Adjustable Width Control Yes
Digital or Analog Digital
Tens Timer Yes
Product Type Tens Combo
Power Supply A/C Adapter/Batteries
Total Size 17.82

 

Channel: Four, Isolated Between Channels
Pulse Amplitude: Adjustable, 0-80 mA peak into 500 ohm load each channel
Wave Form: Asymmetrical Bi-Phasic Square Pulse
Voltage: 0 to 40V (Load: 500 ohm)
Power Source: Four 1.5V AA batteries or DC 9V/800mA adaptor
Size: 13.8cm(L) x 7.8cm(W) x 2.8cm(H)
Pulse Rate: Adjustable, from 2 to 150 Hz, 1 Hz/step
Pulse Width: Adjustable, from 50 to 300 microseconds, 10 us/step
On Time: Adjustable, 2-90 seconds , 1 Sec./ step
Off Time: Adjustable, 0-90 seconds , 1 Sec./ step
RampTime: Adjustable, 1-8 seconds, 1 Sec./ step, The "On" time will increase and decrease in the setting value
Five TENS Modes: B (Burst), N (Normal), M (Modulation), SD1 ( Strength Duration), SD2
Three EMS Modes: C (Constant) S (Synchronous), A (Alternate)
Burst Mode: Adjustable, 0.5 - 5Hz Pulse width adjustable, 50~300|is Frequency fixed = 100 Hz
 
Normal Mode: The pulse rate and pulse width are adjustable. It generates continuous stimulation based on the setting value.
 
Modulation Mode: Modulation mode is a combination of pulse rate and pulse width modulation. The pulse rate and width are automatically varied in a cycle pattern. The pulse width is decreased by 50% from its original setting in 0.5 second, then the pulse rate is decreased by 50% from its original setting in 0.5 second.Total cycle time is 1 second. In this mode, pulse rate (2-150Hz) and pulse width (50-300ns) are fully adjustable.
 
SD1 Mode: The SD1 (Strength-Duration) mode consists of automatic modulation intensity and pulse width in 40% range. The intensity is always increasing while the pulse width is decreasing and vice-versa. The intensity is decreased by 40% while the pulse width is increased by 40% in 5 seconds. In the next 5 seconds, the intensity is increased by 40% while the pulse width is decreased by 40%.Total cycle time is 10 seconds. Pulse rate (2~150Hz) and pulse width (50~300ns) are fully adjustable.
 
SD2 Mode: The SD2 (Strength-Duration) mode consists of automatic modulation intensity and pulse width in 70% range. The intensity is always increasing while the pulse width is decreasing and vice-versa. The intensity is decreased by 70% while the pulse width is increased by 70% in 5 seconds. In the next 5 seconds, the intensity is increased by 70% while the pulse width is decreased by 70%.Total cycle time is 10 seconds. Pulse rate( 2~150Hz) and pulse width (50-3001's) are fully adjustable.
 
Constant Mode (C): Constant stimulation based on setting value. Only pulse width, pulse rate and timer are adjustable in this mode. "Constant" is equalto the "Normal" mode of a TENS unit.
 
Synchronous Mode (S): Stimulation of both channels occurs synchronously. The "ON" time including "Ramp Up" and "Ramp Down" time. Therefore, the setting of ON Time should be no less than two times of the "Ramp" time in this mode. ON TIME > Ramp up + Ramp down
 
Alternate Mode (A): The stimulation of the CH2 will occur after the 1st contraction of CH1 is completed. In this mode, the setting of ON Time should be no less than two times of the "Ramp" time. The OFF Time should be equal or more than the ON Time. ON TIME >Ramp up + Ramp down OFF TIME >ON TIME
 
Timer: Two Adjustable timers, from 1 to 60 minutes or Continuous. Adjustable in 1 minute each step from 1 to 15 minutes, and 5 minutes each step from 15 to 60 minutes. Treatment time countdown automatically.
 
Patient Compliance Meter: This unit can store 60 sets of operation records. Total recorded time is 999 hours.
Low Battery Indicator: A low battery indicator will show up when the battery is low.
Operating Condition: Temperature:0°~40°C Relative Humidity: 30%-75% Atmosphere Pressure : 700Hpa~1060Hpa
Remark: There may be up to a +/-5% tolerance of all parameters and +/-20% tolerance of amplitude & voltage.

 

 

 

 

 

 

 

 

 