Twin Stim Plus 3rd Edition- 4 Channel Digital TENS, EMS, IF & Russian Unit

Twin Stim Plus Package Includes:

  • Stimulator Device
  • 4 Lead Wires
  • 2 packages of high quality Self-Adhesive Electrodes
  • 4 AA batteries
  • A/C Power adapter
  • Hard Plastic Carry Case
  • Instruction Booklet

Description

Twin Stim Plus 3rd Edition- 4 Channel TENS, EMS, IF & Russian (New 4 Modalities)

The Twin Stim Plus is a high quality 4 channel, 8 electrodes,

TENS, EMS, IF and Russian Combo

Users can now select from 4 different modality modes and

operate the device through 4 individual channels with 8 electrodes. 

You can use this device for TENS, EMS, IF and Russian stimulation applications.  With a stronger than ever processor, this device gives

physicians and patients the capability of having a "Clinical" style

device in a portable version.

Product Specifications:


Description:
Channels: 4 Channel, isolated between channels
Pulse Amplitude: Adjustable, 0-80 mA peak into 500 ohm load each

channel.
Voltage: 40 Volts peak to peak on 500 ohms load
Timer: Adjustable, from 1 to 60 minutes.
1 Year Manufacturer Warranty

Twin Stim Plus Package Includes:

  • Stimulator Device
  • 4 Lead Wires
  • 2 packages of high quality Self-Adhesive Electrodes
  • 4 AA batteries
  • A/C Power adapter
  • Hard Plastic Carry Case
  • Instruction Booklet

Product Details:

Twin Stim Plus 3rd Edition Digital TENS EMS IF and Russian Unit with AC Adapter
Newly Updated! Now get the benefits of both TENS EMS IF and Russian in a single unit with the Twin Stim 3rd Edition.

The Twin Stim Plus 3rd Edition is a quad channel TENS/EMS/IF/Russian combinational unit. The unit gives the user the choice of 14 adjustable modes between the four different electrotherapy waveforms and can be powered by 4 AA batteries or by the AC adapter. The Twin Stim Plus 3rd Edition can be used for Acute or Chronic Pain, Muscle Atrophy and Rehabilitation, or Muscle Toning and Strengthening. The unit includes an adjustable timer, safety amplitude cap, a sturdy belt clip and a Quick Start Guide to help user with the unit. The Twin Stim Plus 3rd Edition can be used with 2 to 8 electrodes at a time. The Patient Compliance Meter can store up to 60 sets of operational records (a total of 999 hours). So whether your pain is originating from the nerves, muscle, or tissues the Twin Stim Plus 3rd Edition TENS/EMS/IF/Russian Unit is an effective solution.

  • TENS and Interferential (IF) offer highly effective drug-free pain management.
  • EMS and Russian offer muscle spasm relaxation, muscle strengthening, recovery enhancement and increase in range of motion
  • Quad Channel Unit for use with 2 to 8 electrodes
  • Includes: Timer, Sturdy Belt Clip & Safety Amplitude Cap
  • FDA Approved
  • 14 Adjustable Modes:
    • 5 TENS Modes: Burst, Normal, Modulation, Strength Duration 1 and 2
    • 3 EMS Modes: Constant, Synchronous and Alternate
    • 3 Interferential Modes: Normal, Modulation and Modulation 1
    • 3 Russian Modes: Normal, Modulation and Modulation 1

View the Instruction Manual: pdf manual Twin Stim Plus 3rd Edition Instruction Manual
 

Questions: Call Manufacturer at 1-800-871-7858 or www.CurrentSolutionsNow.com

Features:

  • Channel: Four, isolated between channels
  • Wave Form: Bi-Phasic Square Pulse
  • Output Intensity: 0 - 40Vpp (at 500 ohm load)
  • Power Source:
    • DC 6V, 4xAA 1.5V battery
    • AC Adapter output: DC 9V, 800 mA
  • Size: 5.4" (L) x 3.1" (W) x 1.1" (H) (13.8 x 7.8 x 2.8 cm)
  • Weight: 1 lb (425 g) with battery
  • Pulse Rate:
    • TENS/EMS: 2 - 150 Hz, 1 Hz/step
    • IF: 4000Hz - 4150Hz
    • RUSS: Fixed Rate: 2500Hz; Burst Rate: 20Hz-80Hz
  • Pulse Width: 50µs - 300 µs
  • On Time: Adjustable, 2 - 90 seconds, 1 Sec/step
  • Off Time: Adjustable, 0 - 90 seconds, 1 Sec/step
  • Ramp Time: Adjustable, 1-8 seconds, 1 Sec/step, The "On" time will increase and decrease the setting value
  • Treatment Time: 2 Adjustable Timers from 1-60 minutes or continuous
    • Adjustable in 1 minute in 1-15 minutes
    • Adjustable in 5 minutes in 15-60 minutes
  • Patient Compliance Meter: Unit can store 60 sets of operation records, Total recorded time is 999 hours.

Modes:

  • TENS Modes (5):
    • Burst (B)
    • Normal (N)
    • Modulation (M)
    • Strength-Duration (SD1)
    • Strength-Duration (SD2)
  • EMS Modes (3):
    • Constant (C)
    • Synchronous (S)
    • Alternate (A)
  • IF Modes (3): Normal, Modulation and Modulation 1
    • Normal (N)
    • Modulation (M)
    • Modulation 1 (M1)
  • Russian Modes (3): Normal, Modulation and Modulation 1
    • Normal (N)
    • Modulation (M)
    • Modulation 1 (M1)

Uses:

  • TENS and IF (Interferential):
    • Symptomatic relief of acute or chronic pain
    • Reduction in inflammation
    • Post-traumatic acute pain and edema
    • Post-surgical acute pain and edema
    • Pain relief for back, foot, shoulder, neck, virtually any acute or chronic pain
  • EMS and Russian:
    • Relaxation of muscle spasms
    • Increasing local blood circulation
    • Muscle re-education
    • Immediate post-surgical stimulation of calf muscles to prevent deep vein thrombosis (DVT)
    • Prevention of retardation of disuse atrophy
    • Maintaining or increasing range of motion

Package Includes:

  • Twin Stim Plus 3rd Edition Unit
  • 4 Lead Wires
  • 8 Self-Adhesive Electrodes
  • 4 AA Batteries
  • Carrying Case
  • Sturdy belt clip
  • Instruction Booklet
  • 1 Year Manufacturer Warranty

Warnings:

  • Long term effects of chronic electrical stimulation are unknown.
  • Stimulation should not be applied over the carotid sinus nerves, particularly in patients with a known sensitivity to the carotid sinus reflex.
  • Stimulation should not be applied over the neck or mouth. Severe spasm of the laryngeal and pharyngeal muscles may occur and the contractions may be strong to close the airway or cause difficulty in breathing.
  • Stimulation should not be applied transthoracically in that the introduction of electrical current into the heart may cause cardiac arrhythmias.
  • Stimulation should not be applied transcerebrally.
  • Stimulation should not be applied over swollen, infected, or inflamed areas or skin eruptions.
  • Stimulation should not be applied over, or in proximity to, cancerous lesions.

Roscoe Medical, Inc.